82779203 82779303 83212141
Applications
Industrial automation machinery
Industrial control system
Mechanical and electrical equipment
Electronic instruments, equipments or apparatus
Household applications
SPECIFICATION
Model |
ZLD-150-12 |
|
OUTPUT |
DC VOLTAGE |
12V |
RATED CURRENT |
12.5A |
|
CURRENT RANGE |
0 ~ 12.5A |
|
RATED POWER |
150W |
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
|
VOLTAGE ADJ. RANG |
10.2 ~ 13.8V |
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
|
LINE REGULATION Note.4 |
±0.5% |
|
LOAD REGULATION Note.5 |
±0.5% |
|
SETUP, RISE TIME |
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
|
HOLD UP TIME (Typ.) |
40ms/230VAC 35ms/115VAC at full load |
|
INPUT |
VOLTAGE RANGE |
85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC) |
FREQUENCY RANGE |
47 ~ 63Hz |
|
EFFICIENCY (Typ.) |
87.50% |
|
AC CURRENT (Typ.) |
2.8A/115VAC 1.6A/230VAC |
|
INRUSH CURRENT (Typ.) |
COLD STAR 60A/230VAC |
|
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|
PROTECTION |
OVER LOAD |
110 ~ 140% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||
OVER VOLTAG |
13.8 ~ 16.2V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
||
OVER TEMPERATURE |
Shut down o/p voltage, re-power on to recover |
|
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70°C(Refer to "Derating Curve") |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-40 ~ +85°C, 10 ~ 95% RH |
|
TEMP. COEFFICIEN |
±0.03%/(0 ~ 50°C) |
|
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
|
OTHERS |
MTBF |
601K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION |
159*97*30mm (L*W*H) |
|
PACKING |
0.48Kg ; 30pcs/15.4Kg/0.75CUFT |
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
Copyright © 2025 All Rights Reserved to
Shenzhen Homelux Intelligent Technology Co., Ltd